-40%

NEWEST Injection Infusion Syringe Pump Injector Audible Visual Alarm Fluid Warm

$ 268.75

Availability: 100 in stock
  • Condition: New
  • All returns accepted: Returns Accepted
  • Return shipping will be paid by: Buyer
  • Refund will be given as: Money Back
  • Infusion Rate: 0.1ml/h---1200ml/h
  • Purge Rate: 100ml/h---1200ml/h
  • Brand: Unbranded
  • Rate Accuracy: within±5%
  • Restocking Fee: No
  • Item must be returned within: 30 Days
  • MPN: Does Not Apply

    Description

    Description:
    Infusion Pump
    SKU:100117
    Features:
    1. Audible and visual alarm for occlusion, empty, low battery, end of infusion, door open, wrong setting etc, which gain patents
    2. HD LCD Display, high capacity words, friendly user interface, dynamically display working status
    3. Compatible with any brand of infusion sets after correct calibration
    4. Preset Solution Volume to greatly reduce the workload of nurses
    5. Work mode: ml/h and drop/min can switch freely
    6. Three levels of occlusion: high, middle and low
    7. Purge function
    8. KVO: KVO (keep-vein-open) automatically opens as infusion is completed.
    9. Power Source: AC100-240V, 50/60Hz; Internal Battery
    10.Automatically record the settings of last infusion can be available per customers' request
    11. language: English, Poland, Latvian, Russian etc
    Specification:
    1. Infusion Rate 0.1ml/h---1200ml/h (1ml/h step ,input 016 when set the rate from 800 to 1200ml/h)
    2. Rate Accuracy within±5% (after correct calibration)
    3. Purge Rate 100ml/h---1200ml/h(can be calibrated)
    4. Volume Limit 0ml---9999ml
    Total Infusion Volume  0---9999.9 ml
    5. Alarm Pressure High:800mmHg±200mmHg(106.7kPa±26.7kPa)
    Medium:500mmHg±100mmHg(66.7kPa±13.3kPa)
    Low:300mmHg±100mmHg(40.7kPa±13.3kPa)
    6. Alarms             end of injection, occlusion, door open, bubbles in the tube, wrong setting,
    low battery, AC power pulled out etc
    7. Power source 100V---240V  50/60Hz
    8. Internal rechargeable Li battery volume≥1,600mAh
    4 hours internal battery backup
    9. Bubble Detector ultrasonic wave detector, detection sensitivity ≥25μL
    10. KVO Speed 1ml/h---5ml/h (1ml/h step)
    11. Power Consumption 15VA
    12. Operation Environment Temperature  +5----+40 degree
    Relative Humidity  20----90%
    Storage Temperature  -30-----+55 degree
    Humidity   ≤95%
    Atmospheric Pressure  50.10KPa----106.0KPa
    13. Weight 1.8kg
    14. Dimension 140mm (L)x 157mm (W)x 220mm (H)
    15. Infusion set brand Compatible with any brand
    16.Forbidden Not support blood Infusion
    17. Package 1pc per each Carton, 2.8KG; 24cm (L) x 26cm (W) x 31cm (H)
    2pc per each Carton, 5.8KG; 52cm (L) x 30cm (W) x 36cm (H)
    3pc per each Carton, 9KG; 76cm (L) x 30cm (W) x 36cm (H)
    FDA declaration:
    """"The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.""""
    (Seller name: Rosy Yu  City: Beijing State: Beijing  Country: China  Phone : +86 18663547811)
    The Fingertip Pulse Oximeter is certified with the US FDA 510K No. K070371, the CE & TUV of Eureope and it is on the Australian Register of Therapeutic Goods (ARTG) with the code 136606.
    The Powered Surgical Instrument / Speed 808 System is certified with the US FDA 510(k) Number:K132989
    The Powered Surgical Instrument / Hair Remove Device is certified with the US FDA 510(k) Number:K180353
    The Powered Surgical Instrument / Hair Remove System is certified with the US FDA 510(k) Number:K141973
    massager, vacuum, light induced heating / Slimming Treatment Device is certified with the US FDA 510(k) Number:K161892