-40%

FLUKE 1625-2 ADVANCED GEO EARTH GROUND TESTER 2571664 W\ AUTO FREQUENCY CONTROL

$ 1367.51

Availability: 100 in stock
  • MPN: 1625-2
  • Condition: New
  • All returns accepted: Returns Accepted
  • Brand: Fluke
  • Restocking Fee: 20%
  • Return shipping will be paid by: Buyer
  • Refund will be given as: Money Back
  • Item must be returned within: 30 Days

    Description

    SERIOUS BUYERS ONLY!
    PLEASE READ STORE DETAILS CAREFULLY!
    *** BRAND NEW ***
    FLUKE 1625-2 ADVANCED GEO EARTH GROUND TESTER 2571664 W\ AUTOMATIC FREQUENCY CONTROL
    MSRP:
    379
    Item Details:
    Manufacturer:
    FLUKE
    Description from Manufacturer:
    Product overview: Fluke 1625-2 GEO Earth Ground Tester
    Fluke 1625-2 Earth Ground Tester offers fast, accurate earth ground testing using all four test methods.
    The Fluke 1625-2 earth ground tester measures earth ground loop resistances using only clamps, only stakes, or one clamp and stakes. With the stakeless test method, the Fluke 1625-2 is able to measure earth ground loop resistances for multi-grounded systems using only current clamps. This technique eliminates the dangerous, and time consuming job of disconnecting parallel grounds, and finding suitable locations for auxiliary ground stakes. This allows you to perform earth ground tests in places you’ve not considered before, such as inside buildings, on power pylons, or anywhere you don’t have access to soil.
    Keep your options open
    If a bonded earth ground system does not exist for the building or structure under test, and there is only one path to ground, you can use the 1625-2 to perform the fall-of-potential test method with stakes.
    The 1625-2 offers other advanced features including:
    Automatic Frequency Control to identify existing interference and choose a measurement frequency to minimize its effect, thus providing a more accurate earth ground value.
    R* measurement that calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to earth ground would see.
    The 1625-2 is also very easy to use. World class accessories speed set up and test time. And the tester tells you which stakes or clamps to connect for each test. The large rotary switch and buttons are easy to operate even with a gloved hand. And you can store up to 1500 records and access them easily via the USB port.
    Other useful capabilities:
    Provides R* measurement that calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to earth ground would see
    Includes USB port for data storage and transfer
    Features IP56 rating for outdoor use
    Offers adjustable limits for quicker testing
    Comes with a rugged carrying case
    Key features
    A unique earth ground tester that performs testing with and without stakes
    Tests 3- and 4-pole fall-of-potential, and 4-pole soil resistivity (with stakes)
    Performs selective earth ground rod testing (one clamp + stakes)
    Performs stakeless earth ground rod testing (two clamps)
    Features Automatic Frequency Control (AFC) to minimize the effect of interference
    General Specifications
    Memory
    Internal memory storage up to 1500 records accessible via USB port
    Measuring function
    Interference voltage and frequency, earthing resistance 3- and 4-pole with/without clip-on current transformer, resistance 2-pole with AC, 2- and 4-pole with DC
    Display
    4 digit (2999 Digit) - 7 segment liquid crystal display, with improved visibility
    Operation
    Central rotary switch and function keys
    Temperature Range
    Operating temperature
    -10°C to 50°C (14°F to 122°F)
    Storage temperature
    -30°C to 60°C (-22°F to 140°F)
    Temperature coefficient
    ±0.1% of reading/°C < 18°C > 28°C
    Type of protection
    IP56 for case, IP40 for battery door according to EN60529
    Max voltage
    Warning – socket "clamp" to socket E, ES, S or H
    Urms = 0 V
    Sockets E, ES, S or H to each other in any combination, max. Urms = 250 V (pertains to misuse)
    Safety
    Protection by double and/or reinforced insulation. Max. 50 V to earth per IEC61010-1. Pollution degree 2
    Quality standard
    Developed, designed and manufactured to comply with DIN ISO 9001
    External field influence
    Complies with DIN 43780 (8/76)
    Auxiliary power
    6 x 1.5 V alkaline (IEC LR6 or type AA)
    Battery life span
    With IEC LR6/type AA: typ. 3,000 measurements (RE+RH ≤ 1 kΩ)
    With IEC LR6/type AA: typ. 6,000 measurements (RE + RH > 10 kΩ)
    Dimensions (W x H x D)
    250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in)
    Weight
    ≤ 1.1 kg (2.43 lb) without accessories 7.6 kg (16.8 lb) incl. accessories and batteries in carrying case
    Case material
    Polyester
    Measurement of Interference Voltage DC + AC (UST)
    Measuring limits of error: method
    Full wave rectification
    Measuring range
    1 V to 50 V
    Display range
    0.0 V to 50 V
    Resolution
    0.1 V
    Frequency range
    DC/AC 45 Hz to 400 Hz sine
    Accuracy
    ±(5% of rdg + 5 digit)
    Measuring sequence
    Approx. 4 measurements/s
    Internal resistance
    Approx. 1.5 MΩ
    Max. overload
    Urms = 250 V
    Measurement of Interference Frequency (F)
    Measuring limits of error: method
    Measurement of oscillation period of the interference voltage
    Measuring range
    6.0 Hz to 400 Hz
    Display range
    16.0 Hz to 299.9 Hz to 999 Hz
    Resolution
    0.1 Hz to 1 Hz
    Range
    1 V to 50 V
    Accuracy
    ±(1% of rdg + 2 digit)
    Earthing Resistance (RE)
    Measuring method
    Current and voltage measurement with probe as IEC61557-5
    Open circuit voltage
    20/48 V, AC
    Short circuit current
    250 mA AC
    Measuring frequency
    94, 105, 111, 128 Hz selected manually or automatic. (AFC) 55 Hz in function R1
    Noise rejection
    120 dB (16 2/3 , 50 , 60, 400 Hz)
    Max. overload
    Urms = 250 V
    Electrical Measurement Specifications
    Intrinsic Error or Influence Quantity
    Reference Conditions or Specified Operating Range
    Designation Code
    Requirements or Test in Accordance with the Relevant Parts of IEC 1557
    Type of Test
    Intrinsic error
    Reference conditions
    A
    Part 5, 6.1
    R
    Position
    Reference position ±90°
    E1
    Part 1, 4.2
    R
    Supply voltage
    At the limits stated by the manufacturer
    E2
    Part 1, 4.2, 4.3
    R
    Temperature
    0°C and 35°C
    E3
    Part 1, 4.2
    T
    Series interference voltage
    See 4.2 and 4.3
    E4
    Part 5, 4.2, 4.3
    T
    Resistance of the probes and auxiliary earth electrodes
    0 to 100 x RA but ≤ 50 kΩ
    E5
    Part 5, 4.3
    T
    System frequency
    99% to 101% of the nominal frequency
    E7
    Part 5, 4.3
    T
    System voltage
    85% to 110% of the nominal voltage
    E8
    Part 5, 4.3
    T
    Operating error
    B = ±(|A| + 1,15 √E21 E22 E23 E24 E25 E26 )
    Part 5, 4.3
    R
    B[%] = ± B/fiducial value x 100%
    A = intrinsic error
    En = variations
    R = routine test
    T = type test
    Measuring range
    0.020 Ω to 300 kΩ
    Display range
    0.001 Ω to 2.999 Ω
    3.00 Ω to 29.99 Ω
    30.0 Ω to 299.9 Ω
    0.300 kΩ to 2.999 kΩ
    3.00 kΩ to 29.99 kΩ
    30.0 kΩ to 299.9 kΩ
    Resolution
    0.001 Ω
    0.01 Ω
    0.1 Ω
    1 Ω
    10 Ω
    100 Ω
    Accuracy
    ±(2% of rdg + 2 digit)
    Operating error
    ±(5% of rdg + 5 digit)
    Measuring time
    Typical 8 seconds with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequencies
    Additional error because of probe-and auxiliary earth electrode resistance
    RH(RS + 2000 Ω)/RE x 1.25 x 10-6% + 5 digits
    Measuring error of RH and RS
    Typ. 10% of RE + RS + RH
    Max. probe resistance
    ≤ 1 MΩ
    Max. auxiliary earth electrode resistance
    ≤ 1 MΩ
    Automatic check if error is kept within the limits required by IEC61557-5.
    If after a measurement of probe-, auxiliary earth electrode- and earthing resistance, a measurement error of higher than 30% is assumed because of the influencing conditions, the display shows a warning symbol and a notice that RS or RH are too high.
    Automatic Switchover of Measuring Resolution in Dependence to Auxiliary Earth Electrode Resistance RH
    RH with Umeas = 48 V
    < 300 Ω
    < 6 Ω
    < 60 Ω
    < 600 Ω
    RH with Umeas = 20 V
    < 250 Ω
    < 2.5 kΩ
    < 25 kΩ
    < 250 kΩ
    Resolution
    1 mΩ
    10 mΩ
    100 mΩ
    1 Ω
    Selective Measurement of the Earthing Resistance (RE Clamp)
    Measuring method
    Current and voltage measurement with probe as per EN61557-5 and current measurement in the individual branch with additional current transformer (patent applied for).
    Open circuit voltage
    20/48 V AC
    Short circuit current
    250 mA AC
    Measuring frequency
    94, 105, 111, 128 Hz selected manually or automatically (AFC), 55 Hz (R1)
    Noise rejection
    120 dB (162/3, 50, 60, 400 Hz)
    Max. overload
    Max. Urms = 250 V (measurement will not be started)
    Measuring range
    0.020 Ω to 300 kΩ
    Display range
    0.001 Ω to 2.999 Ω
    3.00 Ω to 29.99 Ω
    30.0 Ω to 299.9 Ω
    0.300 kΩ to 2.999 kΩ
    3.00 kΩ to 29.99 kΩ
    Resolution
    0.001 Ω
    0.01 Ω
    0.1 Ω
    1 Ω
    10 Ω
    Accuracy
    ±(7% of rdg + 2 digit)
    Operating error
    ±(10% of rdg + 5 digit)
    Additional error because of probe- and auxiliary earth typ. electrode resistance
    RH(RS + 2000 Ω)/RETOTAL x 1.25 x 10-6% + 5 digits
    Measuring error of RH and RS
    Typ. of 10% of RETOTAL + RS + RH
    Measuring time
    Typ. 8 sec. with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequencies.
    Minimal current in single branch to be measured
    0.5 mA
    With transformer (1000:1)
    0.1 mA
    With transformer (200:1)
    Max. interference current through transformer
    3 A
    With transformer (1000:1)
    1. With recommended current clamps/transformers.
    Resistance Measurement (R~)
    Measuring method
    Current and voltage measurement
    Measuring voltage
    20 V AC, square pulse
    Short circuit current
    > 250 mA AC
    Measuring frequency
    94, 105, 111, 128 Hz selected manually or automatically (AFC)
    Measuring range
    0.020 Ω to 300 kΩ
    Display range
    0.001 Ω to 2.999 Ω
    3.00 Ω to 29.99 Ω
    30.0 Ω to 299.9 Ω
    300 Ω to 2999 Ω
    3.00 kΩ to 29.99 kΩ
    30.0 kΩ to 299.9 kΩ
    Resolution
    0.001 Ω
    0.01 Ω
    0.1 Ω
    1 Ω
    10 Ω
    100 Ω
    Accuracy
    ±(2% of rdg + 2 digit)
    Operating error
    ±(5% of rdg + 5 digit)
    Measuring time
    Typical 6 seconds
    Max. interference voltage
    24 V, with higher voltages measurement will not be started
    Max overload
    Urms max. = 250 V
    Resistance Measurement (R DC)
    Measuring method
    Current- voltage measurement as per IEC61557-4 possible
    Measuring voltage
    20 V DC
    Short circuit current
    250 mA DC
    Formation of measured value
    With 4-pole measurement wires on H, S, ES can be extended without additional error.
    Resistances > 1 Ω in wire E can cause additional error of 5m Ω/Ω.
    Measuring range
    0.020 Ω to 300 kΩ
    Display range
    0.001 Ω to 2.999 Ω
    3.00 Ω to 29.99 Ω
    30.0 Ω to 299.9 Ω
    300 Ω to 2999 Ω
    3.0 kΩ to 29.99 kΩ
    30.0 kΩ to 299.9 kΩ
    Resolution
    0.001 Ω
    0.01 Ω
    0.1 Ω
    1 Ω
    10 Ω
    100 Ω
    Accuracy
    ±(2% of rdg + 2 digit)
    Operating error
    ±(5% of rdg + 5 digit)
    Measuring sequence
    Approx. 2 measurements/s
    Measuring time
    Typical 4 second including reversal of polarity (2-pole or 4-pole)
    Maximum interference voltage
    ≤ 3 V AC or DC, with higher voltages measurement will not be started
    Maximum inductivity
    2 Henry
    Maximum overload
    Urms = 250 V
    Compensation of Lead Resistance (RK)
    Compensation of lead resistance (RK) can be switched on in functions RE 3-pole, RE 4-pole (clamp), R AC, and R DC 2-pole
    Formation of measured value
    Rdisplay = Rmeasured - Rcompensated2
    2. Value of setpoint entry RK = 0.000 Ω, variable from 0.000 to 29.99 Ω by means of measuring adjustment.
    Stakeless Ground Loop Measurement (Two Clamp Stakeless)
    Switch position
    RA 4-pole (two clamp Stakeless)
    Resolution
    0.001 Ω to 0.1 Ω
    Measuring range
    0.02 Ω to 199.9 Ω
    Accuracy
    ±(7% rdg + 3 digit)
    Operating error
    ±(10% rdg + 5 digit)
    Measuring voltage
    Vm = 48 V AC (primary)
    Measuring frequency
    128 Hz
    Noise current (IEXT)
    Max. IEXT = 10 A (AC) (RA < 20 Ω)
    Max. IEXT = 2 A (AC) (RA > 20 Ω)
    Measuring principle: Stakeless measurement of resistance in closed loops using two current transformers.
    Automatic range selection.
    The information regarding stakeless ground loop measurements is only valid when used in conjunction with the recommended current clamps at the minimum distance specified.
    Includes:
    GEO Earth Ground Tester
    User's Manual
    Batteries
    Quick Reference Guide
    USB Cable
    Condition:
    NEW
    Auction Details:
    Shipp
    ing:
    All
    domestic
    packages will be shipped out via Fedex, UPS, or USPS within the lower 48 states
    Shipping to Hawaii and Alaska would be extra, and those shipments will be shipped out via USPS priority mail, unless otherwise stated in the auction or negotiated in emails.
    Shipping to APO, RR, or PO box will be handled via USPS and would be extra on certain items, please email us prior bidding.
    Goods will be dispatched the latest in
    2
    business days.
    Goods will be shipped out after the holidays and weekends.
    No local pick
    ups accepted at this time, unless otherwise stated in the auction
    Shipping costs are set at that price to cover some of our costs and packaging and handling fees as well as some of the ebay and paypal fees which add to about 13% of the total end price. Please don't email us to negotiate about the shipping costs.  We are extremely busy, so we might not answer your emails.
    Shipping and handling fees are not negotiable, by bidding on this item the buyer agrees to pay for all the shipping costs
    We ship to any destination in the world.
    INTERNATIONAL BUYERS:
    The International shipping rate is flat rate to most destinations in the world, please email us for additional information.
    California buyers are subject to pay 9% tax.
    International  buyers are responsible for all tax and custom duty charges outside the country.
    Payment:
    U.S. Buyers:
    Credit cards through PayPal
    Please note that we can't accept direct credit card payments at this time
    International Buyers:
    PayPal or Wire
    Payment is due within 6 days of auction closing.
    If payment is not received within this time unless otherwise stated or negotiated, item will be relisted on eBay.
    Terms & Conditions:
    After the auction is closed,
    auction winners should contact us regarding any questions or requests.
    After the auction is closed, payment should be received within 6 days.
    Buyer has 30 days to return the product, return product should be brand new with all original accessories, buyer pays shipping costs.
    Shipping and handling charges are not returnable
    Items will be replaced or exchanged in case of DOA
    If the same item or similar item is not in stock in case of DOA, the buyer will receive a refund back
    We combine shipping to save customers money, however, there will be an additional charge per item, please read the description for each item to find out about the specific fees.
    All buyers are subject to pay all taxes and duty fees inside and outside of the United States,
    Our facilities are closed during the weekends and other holidays and there will be no shipments during these time periods. All packages will go out after the weekend or after the holidays.
    Contact Information:
    Please use ebay message