  • Earth voltage Range: : 0.1V~100.0V
  • Ground Resistance Resolution: 0.001Ω
  • Weight: 1653g
  • Test Voltage Wave: Sine wave
  • DC resistance Range: 0.00Ω~30.00kΩ
  • Refund will be given as: Money back or replacement (buyer's choice)
  • MPN: ETCR3200
  • Warranty: 1 year
  • Selection method:: 0.00Ω-3000Ω
  • Return shipping will be paid by: Buyer
  • Ground Resistance Range: 0.01Ω ~ 30.00 kΩ)
  • Test Frequency: 128Hz/111Hz/105Hz/94Hz(AFC)
  • Features: Clamp
  • Item must be returned within: 30 Days
  • Short-circuit Test Current: AC 20mA max
  • Short-circuit Test Current:: AC 20mA max
  • Caliber of clamp:: Φ68mm
  • Country/Region of Manufacture: China
  • All returns accepted: Returns Accepted
  • Condition: New
  • Brand: VTSYIQI
  • Power Supply:: DC 9V Zi-Mn dry battery R14S 1.5V 6 PCS(battery no included)
  • Restocking Fee: No
  • Current Range: 0.01mA~600A
  • Line Resistance Verification: Automatic calibration
  • Electrode Distance Range:: Can be set 1m-100m
  • Current resoluction: 0.01mA

    Description

    Double Clamp Digital Earth Resistance Tester Soil Resistivity Detector RS232
    Instruction:
    ETCR3200 Double Clamp Earth Resistance Tester
    , through a variety of methods measuring earth resistance (range: 0.01Ω ~ 30.00 kΩ), soil resistivity (range: 0.01Ωm ~ 9000kΩm), earth voltage (range: 0.1 V ~ 100.0 V), grounding lead leakage current, AC current (range: 0.01mA ~ 600A); The tester adopts the precision 4-wire method, 3-wire method, simple 2-wire method, selection method and double-clamp method to measure grounding resistance. Large caliber current clamp design, can measure the grounding system which using large grounding down lead.It can flexibly and accurately measure arbitrary grounding resistance values of single point and mesh grounding and other complex grounding conditions. When measuring parallel grounding, it is unnecessary to disconnect any parallel grounding electrode to maximize the convenience of measurement. Import FFT (fast Fourier transform) technology, AFC (automatic frequency control) technology, ensure the measurement of  high precision, high stability and reliability.
    ETCR3200 Double Clamp Multi-function Grounding Resistance Tester
    is composed of host machine, current clamp, monitoring software, test wires, auxiliary ground rod and communication cable. Host machine with large LCD display, white backlight, bar chart indication, clear at a glance. It can store 2000 sets of data at the same time, through the monitoring software to relize historical access and online real-time monitoring functions, dynamic display, alarm indication and auto shut down, with historical data reading, accessing, saving, reporting, printing and other functions.
    Product Characteristics
    1

    2/3/4-wire method measure earth resistance,Range

    0.00Ω

    30.00kΩ
    2

    Selection method meausre earth resistance, Range: 0.00Ω

    3000Ω
    3

    Doule clamp method measure earth resistance,Range:0.01~100Ω
    4

    Soil resistivity measurement, Range

    0.00Ωm

    9000kΩm
    5

    Earth voltage measurement,Range

    AC 0

    600V
    6

    AC current measurement, Range: 0.01mA

    600A
    7

    Data storage: 2000 sets
    8

    Alarm function: audible and visual alarm
    9

    CT size: Φ68mm
    Specification:
    Power Supply
    LR14 1.5V 6 PCS
    (battery is not included during the shipping)
    LCD Diamension
    124mm×67mm (with backlight)
    Range
    Selection method meausrement: 0.01Ω

    3000Ω
    Doule clamp method measurement: 0.01~100Ω
    2/3/4-wire method measurement: 0.00Ω

    30.00kΩ
    Soil resistivity: 0.00Ωm

    9000kΩm
    DC resistance: 0.00Ω

    30.00kΩ
    Earth voltage: 0.1V

    100.0V
    AC current

    0.01mA

    600A
    Resolution
    Resistance

    0.001Ω
    Soil resistivity: 0.01Ωm
    Current: 0.01mA
    Voltage

    0.1V
    Accuracy
    ±1%rdg±3dgt
    Date Storage
    2000 sets
    Data Upload Function
    With RS232 interface, software monitoring, storage data can be uploaded to  computer, save and print.
    Auto Power-off
    After 15 minutes will auto shut down without any operation
    Power Consumption
    Open Backlight

    45mA Max
    Close Backlight: 25mA Max
    Measurement

    100mA Max (close backlight)
    Working Environment
    -10℃~40℃

    below 80%rh
    Store Environment
    -20℃~60℃

    below 70%rh
    CT Size
    Φ68mm
    Measurement method
    2/3/4-wire method measurement: rated current change-pole method, test current 20mA Max
    Selection method meausrement: rated current change-pole method, test current 20mA Max
    Doule clamp method measurement: non-contact mutual inductance measurement method
    Soil resistivity: -pole method (Wenner method)
    Earth to voltage: average rectification(between P(S)-ES interface)
    AC current

    clamp current sensor measurement
    Test Frequency
    128Hz/111Hz/105Hz/94Hz(AFC)
    Data Mode
    Average value, maximum, minimum
    Line Resistance Verification
    Automatic calibration
    Measurement Time
    Voltage to earth

    about 0.5 second/times
    AC current: about 0.5 second/times
    Earth resistance, Soil resistivity

    about 5 second/times
    Measuring Times
    Over 5000 times(Short-circuit test, measurementinterval time should be at least 30 seconds)
    Short-circuit Test Current
    AC 20mA max
    Open-circuit Test Current
    AC 40V max
    Test Voltage Wave
    Sine wave
    Electrode Distance Range
    Can be set 1m-100m
    Line Voltage
    Measur voltage to earth :  below AC 600V measurement
    Data Hold
    “HOLD” symbol display
    Data Read
    “READ” symbol display
    Overflow Display
    “OL” symbol display
    Auxiliary Ground Test
    With auxiliary earth resistance test function, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ)
    Interference Test
    Recognize interference signal automatically, “NOISE” symbol display when interference voltage exceed 5V
    Alarm Function
    Measurement value exceeds alarm setting value, will “Toot-toot-toot” alarm hint
    Battery Voltage
    When power voltage lower than 7.5V, display low power voltage symbol,and remind to replace battery
    Overload Protection
    Measurement of earth resistance: between each interfaces ofC(H)-E

    P(S)-ES,AC 280V/3 seconds
    Insulation Resistance
    Over 20MΩ (between circuit and shell 500V)
    Withstanding Voltage
    AC 3700V/rms (Between circuit and shell)
    Electromagnetic Features
    IEC61010-4-3,Wireless frequency electromagnetic field≤1V/m
    Suitable Safty Standard
    IEC61010-1 (CAT Ⅲ 300V

    CAT IV 150V

    Pollution Level 2)
    IEC61010-031

    IEC61557-1 (earth resistance)
    IEC61557-5 (soil resistivity)
    JJG 366-2004
    Weight
    1653g
    Tester Dimension
    215mm×190mm×95mm
    Packing :
    Package
    Outer package
    Carton
    Inner package
    Aluminum case
    Accessory
    Meter
    1 PCS
    Current clamp
    2 PCS
    Aluminum case
    1 PCS
    Auxiliary grounding rod

    10x150mm

    4 PCS
    Test cable yellow 10 meters
    1 PCS
    Test cable green 10 meters
    1 PCS
    Test cable red 20 meters
    1 PCS
    Test cable black 20 meters
    1 PCS
    Test cable black1.6 meters
    1 PCS
    Test cable red 1.6 meters
    1 PCS
    RS232 communication cable
    1 PCS
    CD
    1 PCS
    Manual
    1 PCS
    Certificate
    1 PCS
    Warranty Card
    1 PCS