    AEMC 6416 Clamp-On Ground Resistance Tester, 1500Ω
    Model:
    6416
    | Order No:
    2141.01
    Employs stakeless ground loop testing and non-intrusive leakage current measurement, making it ideal for system troubleshooting in commercial, industrial, and utility applications. The 6416 can to take measurements without disconnecting or de-energizing the ground system under test and incorporates visible and audible alarms for dangerous voltage and current levels. Compact and rugged, the 6416 is easy to use in small places and harsh environments.
    Brand:
    AEMC
    Model:
    6416
    Order No:
    2141.01
    Condition:
    NEW
    Description
    AEMC 6416 Clamp-On Ground Resistance Tester, 1500Ω
    Employing a stakeless testing method, the unit’s clamp is placed around the earth ground rod or the connecting cable and a known voltage is induced by one half of the clamp while the current is measured by the other half. Subsequently, the tester automatically determines the ground loop resistance at this grounding connection.
    Eliminating the need to disconnect parallel ground rods and find suitable locations for placing auxiliary ground stakes, the stakeless testing method saves time and enables users such as industrial and utility electricians, and field service electricians and contractors, to perform earth ground loop tests in locations where it is not possible to use other techniques, including inside buildings or on power pylons.
    Further improving the unit’s versatility and security, a contact voltage indication feature that warns when the voltage derived from current and resistance measurements detect a potentially dangerous touch condition, as well as selectable test frequency function that provides more accurate results in inductive environments, have been incorporated.
    Features
    High sensitivity measurement function of leakage current flowing to ground or circulating in ground loops from 0.2 mA to 40 A
    Resistance measurement from 0.01 to 1500 Ω
    Contact voltage indication warns of unsafe conditions
    Selectable test frequency improves accuracy in inductive environments
    Noise icon and buzzer alert user to presence of dangerous voltage and current levels
    Multi-function bright yellow organic display (OLED)
    Data storage function (Ω and/or A) with time-stamping allows to store up to 2000 measurements
    View stored measurements on the OLED display
    Alarm function with adjustable set point and buzzer for quick field checks for volts, amps and ohms
    Alarm settings and stored memory information saved during shutdown
    Battery life information at power-up and auto power off function
    Large jaw opening of 35 mm
    Rugged Lexan® head and body construction resists breakage
    Auto Power OFF function
    Designed to EN61010-1, 600V Cat. IV safety standards
    Applications
    Ground electrode system resistance
    Bonding/continuity checks
    Cell tower grounding verification
    Ground measurements on railroad signalling systems
    Included
    What's included with the AEMC 6416
    Clamp-On Ground Resistance Tester
    Calibration Loop
    Hard Carrying Case
    4 x 1.5 V AA Batteries
    User Manual
    Specifications
    Ground Resistance
    0.010 to 0.099 Ω
    Resolution: 0.001 Ω
    Accuracy (% of reading): ±1.5%, ±0.01 Ω
    0.10 to 0.99 Ω
    Resolution: 0.01 Ω
    Accuracy (% of reading): ±1.5%, ±0.01 Ω
    1.0 to 49.9 Ω
    Resolution: 0.1 Ω
    Accuracy (% of reading): ±1.5%, ±0.1 Ω
    50.0 to 99.5 Ω
    Resolution: 0.5 Ω
    Accuracy (% of reading): ±2%, ±0.5 Ω
    100 to 199 Ω
    Resolution: 1 mA
    Accuracy (% of reading): ±2%, ±1 mA
    200 to 395 Ω
    Resolution: 5 Ω
    Accuracy (% of reading): ±5%, ±5 Ω
    400 to 590 Ω
    Resolution: 10 Ω
    Accuracy (% of reading): ±10%, ±10 Ω
    600 to 1150 Ω
    Resolution: 50 Ω
    Accuracy (% of reading): 20% approximately
    1200 to 1500 Ω
    Resolution: 50 Ω
    Accuracy (% of reading): 25% approximately
    Alarm
    Adjustable from 1 to 199 Ω
    Frequency Selection
    Choice of 50, 60, 128, or 2083 Hz for impedance calculation
    Current Measurement Range (Auto-Ranging)
    0.200 to 0.99 mA
    Resolution: 1 µA
    Accuracy (% of reading): ±2%, ±50 µA
    1.000 to 2.990 mA
    Resolution: 10 µA
    Accuracy (% of reading): ±2%, ±50 µA
    3.00 to 9.99 mA
    Resolution: 10 µA
    Accuracy (% of reading): ±2%, ±50 µA
    10.00 to 29.90 mA
    Resolution: 100 µA
    Accuracy (% of reading): ±2%, ±100 µA
    30.0 to 99.9 mA
    Resolution: 100 µA
    Accuracy (% of reading): ±2%, ±100 µA
    100.0 to 299.0 mA
    Resolution: 1 mA
    Accuracy (% of reading): ±2%, ±1 mA
    0.300 to 0.990 A
    Resolution: 1 mA
    Accuracy (% of reading): ±2%, ±1 mA
    1.000 to 2.990 A
    Resolution: 10 mA
    Accuracy (% of reading): ±2%, ±10 mA
    3.00 to 39.99 A
    Resolution: 10 mA
    Accuracy (% of reading): ±2%, ±10 mA
    Loop Inductance Measurement
    10 to 100 µH
    Resolution: 1 µH
    Accuracy: ±(5% reading +1 µH)
    100 to 500 µH
    Resolution: 1 µH
    Accuracy: ±(3% reading +1 µH)
    Contact Voltage (Touch Voltage) Calculated
    0.1 to 4.9 V
    Resolution: 0.1 V
    Accuracy: ±(5% reading +0.1 V)
    5.0 to 49.5 V
    Resolution: 0.5 V
    Accuracy: ±(5% reading +0.5 V)
    50 to 75 V
    Resolution: 1 V
    Accuracy: ±(10% reading +1 V)
    General Features
    Jaw Opening
    1.38” (35 mm)
    Temperature
    Operating: -4 to +131°F (-20 to +55°C)
    Storage: -22 to +158°F (-30 to +70°C)
    Relative Humidity
    Up to 90% at 104°F (40°C)
    Maximum Overload
    Permanent current: 100 max. 50/60 Hz
    Transient current: (<5s) 200A 50/60 Hz
    Display
    OLED, 152 segments 1.8 x 1.5” (48 x 39 mm)
    Memory
    300 measurements
    Alarm
    3 separate alarms (Ω, V and A)
    Power Source
    4 x 1.5 V LR6 (AA) alkaline batteries or 4 NiMH batteries
    Battery Life
    12 hours or 1440 30-seconds tests approximately
    Terms & Conditions
    Item Condition:
    Unless specified otherwise all products listed are Brand New in the original factory packaging and include a full factory warranty.
    Shipping:
    We currently only ship to U.S. buyers. We ship items within one or two business days from payment. We do not process shipments on weekends and holidays. Local pick up is not available. We only ship to addresses verifiable by either PayPal or credit card issuing bank.
    Please note that we cannot alter the address once a purchase is made. In the case of PayPal payment, we will ship orders when the payment is marked “Eligible” for PayPal Seller’s protection.
    *Shipping Rates are for Continental US, Please Contact us for other US Destinations
    Payment:
    Currently all payments must be made directly though PayPal
    Sales Tax:
    We are required to charge sales tax in North Carolina
    Return Policy:
    If for any reason you are not 100% satisfied with a product you receive from us, you may return the regular stock product within 30 days from the time of receipt, for a full refund or exchange of the product you purchased (less any shipping costs). Within this time, products may be returned; freight prepaid and must be in their original packaging and in resalable condition.
    Shipping errors, missing items or damages must be reported to us immediately (damages should be accompanied by a signed bill of lading acknowledging the damage). Items returned will be inspected for damage or misuse at which time they may be subject to restocking fees, other fees or refused, prior to the issuance of any credit.